Main Features
- It has complete function,excellent configuration,running stably,fully
showing the idea of technology basing on people.
- Its full control engineering nicety ball face launches visual mark launches
visual mark Color of visual mark(red,yellow),degree of visual mark
control(0-1000asb).
- Intensity of background light is controllable.
- Complete test process(standard test from central 10 to peripheral 90 ,
blind spot test, yellow spot test, glaucoma test, visual nerval test,etc)
- Advanced report diagram(3D, grey level cheme,threshold diagram, upright
section drawing, probability drawing, DB drawing, general deviation drawing,
model probability drawing, model probability drawing, accumulating deficit)
- Automatic infrared pupil surveillance, track alarm system
- Advanced file management system(fast classification of file, compression
and back trans-store)
- Glaucoma test: The standard procedure is central 30° -2°
- Department of neurology disease test: To department of neurology patients, the test of central threshold 30 can
discover visual symptom or the partially blind of department of neurology. The test of central 30 can test majority
of department of neurology.
- Retina disease test: It test denaturation of retina pigment and visual deficit happening at peripheral vision. If it only test central vision, it maybe ignores something, so the range should be at least 60 .
- Visual function judgment: Vision is a standard of testing blind. The procedure can choose central 30 - 2 and peripheral 60 -30 ,which almost include whole range of vision.
- Threshold test: center examination, peripheral visual examination, yellow spot examination, user-defined examination of scope, random point test.
- Filtrated examination: periheral-filtrated examination, perimeter 0-75 degree filtrated field examination, perimeter 0-90 degree filtrated field test, user-defined filtrating test.
- Fast threshold test: central visual fast test,peripheral visual fast test.
- Particular test: diabetic rest, neurology test, nasal step examination, central low visual examination, upside of
face droop visual examination,blind spot position examination.
- Glaucoma test: central visual threshold test, glaucoma threshold test, central visual filtrating test, glaucoma
filtrated examination.
- 388 test point in 90 .
- Intensity of LED 0-1000asb.
- Intensity of background light:31.5 asb(controllable)
- No grade gradual stored-program control chin rest automatic adjustment system
- Infrared pupil video surveillance system (automatic track, alarm,pause,restore).
- Strong management system of medical record.
- Standard configuration of mainframe.
|